EDCV double tailgate

Mold clamping system

EDCV double tailgate

Mold clamping system

The EDCV-1 keeps cylinders under pressure, protecting the system from pipe leaks. The EDCV-1 allows two single-acting hydraulic circuits to be connected together.

DOUBLE CHECK VALVE EDCV-1

For added safety, especially on the single acting cylinders mounted on the Slide, a double pilot operated check valve can be installed. EAS Change Systems offers this valve as under the type name EDCV -1.

DOUBLE CONTROL, DOUBLE SECURITY

The EDCV-1 is a double check valve that increases safety on the slide hydraulic clamp circuit:

the operation is basically the same as that of the single check valve CB-1: keeping the cylinders under pressure, even in the event of a leakage in the main hydraulic line between the pump and the double check valve.

As shown in the image below, the Slide Main Pipe (A) is also doubled:

First, there is one main line on the slide plate, and then the valve divides the main line into two circuits connecting the clamping cylinders crosswise. (Think of the corners of a square.)
This ensures that if there is a leakage in one of the two lines after the double check valve EDCV-1, the other line will remain pressurized, keeping half of the clamping systems clamped and preventing the mold from falling.

Would you like to view and test this product?

That's possible! Visit our showroom and technical studio in Zandhoven.